Model 410一氧化氮監測儀-Model 410一氧化氮監測儀

  • 發布日期:
  • 有效日期:
  • 所 在 地:
  • 產  地:
  • 已獲點擊:

  • 2025年2月7日
  • 2025年8月7日
  • 上海上海市
  • 178次

【產品簡介】

Model 410一氧化氮監測儀


【詳細說明】

 

The Model 410 Nitric Oxide Monitor™ is designed for the measurement of atmospheric nitric oxide (NO) in the concentrtion range 0-2,000 ppb (0-2 ppm) with a precison of ±1.5 ppb. When used in combination with the Model 401 NO2 Converter, NOx and NO2 (by difference) are also measured. The detection principle of the Model 410 is based on the selective reaction of NO with ozone. The resulting ozone depletion is measured using the absolute method of UV absorbance and thus requires only infrequent calibration. By comparison, chemiluminescence NOx instruments require nearly continuous calibration using a standard gas.

Theory of Operation

The NOzone™ technology employed by the Model 410 Nitric Oxide Monitor™ is based on the quantitative reaction of nitric oxide (NO) with ozone (O3):

NO + O3 → NO2 + O2 + light (1)

This reaction has long been used as a gas phase titration for the measurement of either NO or O3 in laboratory kinetics experiments, and the reaction is stoichiometric; i.e., one O3 molecule is consumed for every NO molecule oxidized to NO2 in the reaction. In the Model 410 Nitric Oxide Monitor™, a small concentration of ozone (~4 ppm) is added to the gas sample stream and the resulting decrease in concentration of ozone is measured by the absolute method of UV absorption. By providing adequate time for the reaction to go to completion, the decrease in ozone concentration is equal to the original concentration of NO in the gas stream.

Reaction 1 also is used in conventional chemiluminescence analyzers. Instead of measuring the change in ozone concentration, chemiluminescence detects the small amount of light produced in the reaction. That light is emitted by electronically excited NO2 molecules formed in reaction 1. Chemiluminescence instruments are highly sensitive and have a very fast response time, but require frequent calibration using a gas standard.

Figure 1 is a schematic diagram of the Model 410 Nitric Oxide Monitor. Here we trace the gas flow through the instrument beginning at the Air Inlet near the bottom of the diagram.

Model 410
Fig. 1. Schematic diagram of the Model 410 Nitric Oxide Monitor.

A miniature air pump, the Sample Pump, draws sample air into the instrument and through a proprietary heated ozone scrubber at a flow rate of ~0.8-1.2 L/min. The air sample then passes through a miniature solenoid valve which alternay directs the flow through a NOx scrubber or bypass. The flow then passes through a Nafion tube, a flow meter and into an overflow tee which vents part of the air sample. The Nafion tube equilibrates the humidity of the sampled air with that inside the instrument case, assuring that the humidity is the same in NO-scrubbed and unscrubbed air. The Total Flow Pump (top of diagram) draws air from the overflow tee, and through the detection cell. A bleed valve, the Total Flow Adjustment Valve, is used to provide adjustment of the total flow rate through the detection cell. Following the sampling tee, a small flow of 20-30 cc/min of ozonized air is added to the sample air stream. The flow rate of ozone/air is adjusted by use of the Ozone Needle Valve, and is set to produce an ozone concentration in the range of 3.5-4.5 ppm (3,500-4,500 ppb).

The sample air, either NO-scrubbed or unscrubbed, containing the added ozone next passes through a coiled reactor, which provides adequate reaction time (~3 s) for nearly all NO in the sample to react with ozone via reaction (1) above. Correction is made in the software for lack of complete reaction. That correction is typically less than 3%. Next the sample air passes through the Detection Cell where UV light intensity is measured. The air stream then passes through an Ozone Scrubber where O3 is catalytically converted to O2, through an NO2 scrubber to remove the NO2 produced in reaction (1), through the Total Flow Meter where the flow rate is measured, and into the instrument case.

Ozone is produced by pumping ambient air through a chamber containing a low pressure mercury lamp. The lamp has a fused silica window that passes highly energetic atomic emission near 185 nm in addition to the resonant emission at 254 nm. The wavelengths near 185-nm are absorbed by molecular oxygen (O2) to produce oxygen atoms (O). Those oxygen atoms rapidly attach to O2 via a termolecular reaction to form O3.

O2 + photon → 2 O (2)

O + O2 + M → O3 + M (3)

Here, the photon has a wavelength near 185 nm, and M is any molecule, principally N2, O2, Ar and H2O, in air. The molecule M catalyzes the combination of O and O2 by removing excess relative translational energy. The flow rate of ozone/air and thus the ozone concentration is controlled by the Ozone Needle Valve. Flow rates and the actual ozone concentration produced are measured in a cycle at the beginning of an analysis by modulating the Ozone Solenoid Valve. This valve either allows the ozone/air mixture to enter the stream of gas being analyzed or diverts it through an ozone scrubber.

NO is measured by modulating the NO Solenoid Valve. A low-pressure mercury lamp is located on one side of the absorption cells, and a photodiode is located on the opposite side. The photodiode has a built-in interference filter centered on 254 nm, the principal wavelength of light emitted by the mercury lamp. Shorter wavelengths of light that could produce ozone are absorbed by the low-grade quartz envelope of the lamp itself and by the window of the detection cell, which passes 254-nm but not 185-nm light. The state of the NO Solenoid Valve is switched every 10 seconds in order to measure light intensities for sample air, I, and scrubbed sample air, Io. The values of I and Io are used to calculate the concentration of NO in the original air sample. In addition to a small correction for incomplete reaction, a correction is made for the small amount of dilution of the NO concentration by the added ozonized air.

Specifications

 

Measurement Principle
Titration of NO with Ozone with Detection of Ozone Depletion by UV Absorption at 254 nm
Precision and Accuracy
Higher of 1.5 ppb or 2% of reading
Data Storage
14,336 lines (10 s avg. = 1.4 days; 5 min avg = 1.4 mo.)
Time/Measurement
10 s (Data averaging options: 10 s, 1 min, 5 min, 1 hr)
Sample Flow Rate
1 L/min
Data Outputs
RS-232, LCD, 0-2.5 V Analog, 4-20 mA Optional, Flash Card Optional
Power Requirements
Typical: 11.4 watt
Maximum: 22.3 watt (warmup)
Size

13.3 x 8.3 x 5.3 x in
33.7 x 20.0 x 13.3 cm

Weight
8.3 lb (3.7 kg)

    
留言框
感興趣的產品: *
留言內容:
您的姓名: *
您的單位:
聯系電話: *
微信:
常用郵箱:
詳細地址:
省份: *
驗證碼: * =   請輸入計算結果(填寫阿拉伯數字),如:三加四=7
      
| 商鋪首頁 | 公司檔案 | 產品展示 | 供應信息 | 公司動態 | 詢價留言 | 聯系我們 | 會員管理 |
化工儀器網 設計制作,未經允許翻錄必究.Copyright(C) http://www.fzbnjj.com, All rights reserved.
以上信息由企業自行提供,信息內容的真實性、準確性和合法性由相關企業負責,化工儀器網對此不承擔任何保證責任。
溫馨提示:為規避購買風險,建議您在購買產品前務必確認供應商資質及產品質量。
二維碼 在線交流

掃一掃訪問手機站
主站蜘蛛池模板: 阿尔山市| 崇仁县| 上林县| 辰溪县| 西畴县| 那曲县| 贞丰县| 卢氏县| 清水县| 舞阳县| 九江市| 安图县| 通化市| 闻喜县| 巴林左旗| 阿勒泰市| 济南市| 武强县| 九台市| 卓资县| 静安区| 巍山| 永春县| 容城县| 泉州市| 宜良县| 沈丘县| 大同县| 东兰县| 五原县| 岱山县| 仪征市| 青海省| 吉林市| 离岛区| 阳信县| 敦化市| 永和县| 五指山市| 桐柏县| 江门市|